K-UPS
(BATTERY SOLUTIOIN FOR UPS)

Kokam's K-UPS provides optimal protection against an outage in a number of applications including medical, telecom, and data centers. During an outage, our UPS immediately provides battery backup power to protect mission critical information and systems.

Brochure
 

ADVANTAGES

CUSTOMIZATION OF PARALLEL CABINET & RACK CONNECTIONS
Kokam K-UPS series provides a modular, easily scalable solution. Kokam battery's' unique characteristics of high energy density and light weight allow integration of batteries and UPS providing faster and more reliable field installation and start-up.

- Provides noticeably long cycle life and high power density than lead acid batteries
- Minimization of degradation with shallow cycles
- Few open-circuit failure modes during normal operation
- No hydrogen generation
- Integrated monitoring of individual cell’s voltages and temperatures

VRLA (Lead Acid) VS Kokam K-UPS

  1. 1
    High Power 5 times more powerful
    VRLA Kokam K-UPS
    (>10C-Rate)
  2. 2
    Long Cycle life More longer
    VRLA
    (MAX 5 years)
    Other Lithium Battery
    (MAX 10 years)
    Kokam K-UPS
    (MAX 15 years)
  3. 3
    Light Weight 5 times more lighter
    VRLA Kokam K-UPS
  1. 4
    Low Maintenance No Hydrogen gas emissions
    No Hydrogen gas emissions result in lower ventilation costs and safer operation than Lead-Acid
  2. 5
    Small Footprint 3.3 times more space efficient
    VRLA Kokam K-UPS
  3. 6
    Wide Temperature range No additional cooling system
    VRLA
    (20~22˚C)
    Kokam K-UPS
    (18~28˚C)

Long Cycle life

Up to 15 years warranty guaranteed (Back Up Time Guarantee)

    1. 1
    2. 2
    3. 3
    4. 4
    5. 5
    VRLA
    1. 1
    2. 2
    3. 3
    4. 4
    5. 5
    6. 6
    7. 7
    8. 8
    9. 9
    10. 10
    Other Lithium Battery
    1. 0
    2. 1
    3. 2
    4. 3
    5. 4
    6. 5
    7. 6
    8. 7
    9. 8
    10. 9
    11. 10
    12. 11
    13. 12
    14. 13
    15. 14
    16. 15
    Kokam K-UPS

Small Footprint : 40% LESS FOOTPRINT, 5 TIMES LIGHTER

VRLA (Lead Acid)

- 10 Total Rack System Wt. / 66,000 Lbs.
- 400”W x 30”D = 83.3ft²
- 2,250kW / 100ft² = 27.0kW/ft²

60 in200 in
Kokam K-UPS

- 8 Total Rack System Wt. / 13,000 Lbs.
- 280”W x 25”D = 48.6ft²
- 2,250kW / 48.6ft² = 46.3kW/ft²

50 in140 in

K-UPS COMPONENT

2 Pole K-UPS

3 Pole K-UPS

Fire Suppression & Fan Battery Protection Unit (BPU)
-String BMS
- Switch Disconnector
- Fuse
- Contactor
Switched Mode
Power Supply (SMPS)
Battery Module
(incl. Module BMS)
Rack Cover

SPECIFICATION

Ultra High Power – 2 pole UPS Battery

Back Up Time Up to 10 minutes
Rack Configuration 120S 132S 140S 160S
Installed Energy (kWh, @ BOL) 33.3 36.6 38.8 44.4
Module Configuration 30S1P x 4 33S1P x 4 35S1P x 4 32S1P x 5
Voltage Range (Vdc) 384~492 422~541 448~574 512~656
Float Voltage (Vdc) 480~491 528~540 560~573 520~655
Continuous Discharge Power (kW, 5min) 266 293 310 355
Peak Discharge Power (kW, 1min) 333 366 388 444
Dimension (WxDxH, mm) 580 x 740 x 1,960 580 x 740 x 1,960 580 x 740 x 1,960 780 x 626 x 2,237
Weight (kg) < 500 < 550 < 600 < 700
Cell Capacity (Ah) 75 75 75 75
Peak Discharge Current (A) 870 870 870 870
Certification UL, IEC, UN38.3

High Power – 2 pole UPS Battery

Back Up Time from 10 to 30 minutes
Rack Configuration 120S 132S 140S 144S
Installed Energy (kWh, @ BOL) 37.5 41.2 43.7 45.0
Module Configuration 30S x 4 33S x 4 35S x 4 36S x 4
Voltage Range (Vdc) 384~492 422~541 448~574 590~461
Dimension (WxDxH, mm) 580 x 740 x 1,960 580 x 740 x 1,960 580 x 740 x 1,960 580 x 740 x 1,960
Weight (kg) < 500 < 550 < 600 < 625
Cell Capacity (Ah) 85 85 85 85
Peak Discharge Current (A) 580 580 580 580
Certification UL, IEC, UN38.3

3 pole UPS Battery

Back Up Time 10mintues to 30mintues
Rack Configuration 66S+66S 60S+60S 66S+66S 100S+100S 2P100S+2P100S
Installed Energy
(kWh, @ BOL)
36.6 37.5 41.2 55.5 147.2
Module
Configuration
22S1P x 3
22S1P x 3
30S1P x 2
30S1P x 2
33S1P x 2
33S1P x 2
20S1P x 5
20S1P x 5
20S2P x 5
20S2P x 5
Voltage Range (Vdc) 192~246 192~246 212~270 320~410 320~410
Dimension (WxDxH, mm) 780 x 676 x 1,900 580 x 740 x 1,960 580 x 740 x 1,960 780 x 676 x 2,237 1170 x 780 x 2,237
Weight (kg) 550 500 550 840 840
Capacity (Ah) 75 *85 85 85 100
Certification UL, IEC, UN38.3
HIGHLY SCALABLE AND EASILY TAILORED
Kokam's UPS (K-UPS), which is composed of Kokam’s SLPBs, is light in weight and small in size, due to its high energy density. It can hence be placed in restricted spaces and the maintenance is rather easy due to convenient accessibility.
Also, when compared to lead acid batteries of the same weight and volume, output performance of Kokam SLPB is significantly higher. Kokam's UPS can further be classified in two types : short term (minutes) and long term (hours) backup power systems.
KEY STRENGTHS
  • High Power Output
  • Small Volume Footprint
  • Flexible Design
  • Essential backup power to protect critical information and systems
  • Outstanding safety performance
APPLICATIONS

Installed in various locations and supplies emergency back-up power during an outage :

  • - Data center
  • - Financial institution
  • - Semi-conductor factory
  • - Medical facility